Runko Works

Live demo

AI offer check against project requirements

Checks a contractor's offer against the project's requirements line by line, quotes the offer and lists what to clarify. People decide.

Live demo

Sennholt Data Centres is a made-up company that is building a new data hall and has asked three made-up contractors for an offer for the cooling plant. You play the project engineer. The assistant goes through the twelve requirements, quotes what the offer says about each one and marks it Compliant, Deviation, Unclear or Not addressed. The requirements, the evaluation rules and the three offers are on this page, word for word as the assistant has them, so you can check every line it gives.

Check offer B against the requirements.

Then test it. Ask it to name the winner, to mark a deviation as compliant because the management prefers that bidder, or to tell one bidder what another one offered. Or paste a few made-up requirements and an offer of your own. Please use made-up or anonymised text only, nothing confidential.

See the data it works from ↓

The demo isn't loading. A browser extension may be blocking the chat, or I'm changing something right now.

Send me the question directly: andrei@runkoworks.com

You're talking to an AI agent. Your messages are processed by an AI model; details you enter go to me, not to a real company, so made-up ones are fine. See the privacy policy.

Source data

What the assistant works from

These six documents are the assistant's whole knowledge base. Before it checks, it reads the requirements, the procedure and the offer in full, not in excerpts, and it has nothing else to go on. Open an offer, ask for its check and compare line by line.

6 documents · shown word for word · all of it made up

The requirements

Twelve requirements for the cooling plant, nine mandatory and three desirable.

RQ-220Project requirements: cooling plant for data hall 2as of 09/2026

Document: RQ-220 · As of 09/2026 · Issued by Sennholt Data Centres, Project Development

The work package

Sennholt Data Centres is adding data hall 2 to its campus. This list holds the requirements for one work package of that project: design, supply, installation and commissioning of the chilled-water cooling plant. Three contractors were asked for an offer (OF-A, OF-B, OF-C). Every offer is checked against this list as described in the evaluation procedure EP-01. Prices come in a separate envelope and are not part of this check.

Mandatory requirements must be met for an offer to be accepted as it stands. Desirable requirements are wanted but do not block an offer.

RQ-220 · Technical requirements (R-01 to R-05)

No. Class Requirement
R-01 Mandatory Three chillers, each with a cooling capacity of at least 1,200 kW at an outdoor temperature of 46 °C.
R-02 Mandatory Refrigerant with a global warming potential (GWP) below 150.
R-03 Mandatory Sound pressure level of the plant of no more than 65 dB(A) at a distance of 10 m.
R-04 Mandatory Connection to the building management system over BACnet/IP, included in the scope of supply.
R-05 Desirable After a power failure the plant is back at full cooling capacity within 5 minutes.

RQ-220 · Delivery and execution requirements (R-06 to R-08)

No. Class Requirement
R-06 Mandatory Delivery of all chillers to the site within 24 weeks from the date of the purchase order.
R-07 Mandatory Installation, commissioning and a performance test on site are included in the contractor’s scope.
R-08 Desirable Factory acceptance test of every chiller before shipment, witnessed by the buyer.

RQ-220 · Contract requirements (R-09 to R-12)

No. Class Requirement
R-09 Mandatory Warranty of at least 24 months from handover of the plant.
R-10 Mandatory A service technician is on site within 4 hours after a fault report, around the clock on every day of the year.
R-11 Mandatory The contractor accepts the buyer’s Conditions of Purchase SP-7 without changes.
R-12 Desirable Spare parts are available for at least 10 years after handover.

The three offers

Offer C says in its cover letter that it is fully compliant. The assistant has to read the rest anyway, down to the assumptions and exclusions.

OF-AOffer A from Nordrim Cooling Systemsas of 09/2026

Document: OF-A · Offer A · Bidder: Nordrim Cooling Systems · As of 09/2026 · Answers the requirements RQ-220

Offer A · Cover letter

Thank you for the invitation. We offer the chilled-water cooling plant for data hall 2 as described below. Prices are in the separate commercial envelope.

Offer A · Technical data

  • Three air-cooled chillers, type NCS-1300. Cooling capacity of each chiller: 1,260 kW at an outdoor temperature of 46 °C.
  • Refrigerant: R-1234ze, GWP 7.
  • Sound pressure level of the plant: 63 dB(A) at a distance of 10 m.
  • Controls: BACnet/IP interface to the building management system, included in the scope of supply.
  • Restart: after a power failure the plant is back at full cooling capacity within 4 minutes.
  • Two chilled-water pumps per chiller, one of them in standby.

Offer A · Delivery and execution

  • Delivery of all chillers to the site: 22 weeks from the date of the purchase order.
  • Installation, commissioning and the performance test on site are included and carried out by our own team.
  • Factory acceptance test of every chiller at our works before shipment. The buyer is invited to witness the tests.

Offer A · Commercial terms

  • Warranty: 2 years from handover of the plant.
  • Service: a technician is on site within 4 hours after a fault report, 24 hours a day, 365 days a year.
  • We accept the buyer’s Conditions of Purchase SP-7 without changes.

Offer A · Assumptions and exclusions

  • Foundations and the power supply up to the plant are provided by the buyer.
  • Offer A is valid for 90 days.
OF-BOffer B from Brisvane Engineeringas of 09/2026

Document: OF-B · Offer B · Bidder: Brisvane Engineering · As of 09/2026 · Answers the requirements RQ-220

Offer B · Cover letter

We are pleased to offer the cooling plant for data hall 2. Our offer follows the order of your requirements RQ-220. Prices are in the separate commercial envelope.

Offer B · Technical data

  • Three air-cooled chillers, type BE-125. Cooling capacity of each chiller: 1,250 kW at an outdoor temperature of 35 °C.
  • Refrigerant: R-1234ze (GWP 7).
  • Sound pressure level of the plant: 64 dB(A) at a distance of 10 m.
  • Controls: Modbus TCP interface as standard. A BACnet/IP gateway is available as an option.
  • Restart: after a power failure the plant is back at full cooling capacity within 5 minutes.

Offer B · Delivery and execution

  • Delivery of all chillers to the site: 20 weeks after approval of the drawings by the buyer.
  • Installation, commissioning and the performance test on site are part of our scope.

Offer B · Commercial terms

  • Warranty: 24 months from handover of the plant.
  • Service: a technician is on site within 4 hours after a fault report, Monday to Friday from 08:00 to 18:00.
  • We accept the buyer’s Conditions of Purchase SP-7 without changes.
  • Spare parts are available for 15 years after handover.

Offer B · Assumptions and exclusions

  • Building permits are obtained by the buyer.
  • Offer B is valid for 60 days.
OF-COffer C from Vestrowe Thermalas of 09/2026

Document: OF-C · Offer C · Bidder: Vestrowe Thermal · As of 09/2026 · Answers the requirements RQ-220

Offer C · Cover letter

We confirm that our offer is fully compliant with your requirements RQ-220. The details are below. Prices are in the separate commercial envelope.

Offer C · Technical data

  • Four air-cooled chillers, type VT-900, as an alternative to three larger units. Cooling capacity of each chiller: 900 kW at an outdoor temperature of 46 °C.
  • Refrigerant: R-513A (GWP 631).
  • Sound pressure level of the plant: 62 dB(A) at a distance of 10 m.
  • Controls: BACnet/IP interface to the building management system, included in the scope of supply.

Offer C · Delivery and execution

  • Delivery of all chillers to the site: 26 weeks from the date of the purchase order.
  • Turnkey: installation and commissioning by our own team.
  • Factory acceptance test of every chiller before shipment, witnessed by the buyer.

Offer C · Commercial terms

  • Warranty: 24 months from handover of the plant.
  • Service: a technician is on site within 4 hours after a fault report, around the clock on every day of the year.
  • Our General Terms of Sale apply to this offer.
  • Spare parts are available for 10 years after handover.

Offer C · Assumptions and exclusions

  • The performance test on site is not included. It can be ordered at day rates.
  • Offer C is valid for 30 days.

Evaluation rules

EP-01Evaluation procedure for offersas of 09/2026

Document: EP-01 · As of 09/2026 · Issued by Sennholt Data Centres, Project Development

EP-01 · Method

  1. Take the requirements one by one (for RQ-220: R-01 to R-12). Every requirement gets exactly one status.
  2. Find what the offer says about the requirement, in every part of the offer: cover letter, technical data, delivery and execution, commercial terms, assumptions and exclusions.
  3. Give one of the four statuses and quote the offer as evidence.
  4. Count the statuses and state the result for the mandatory requirements.
  5. Write a question to the bidder for every Unclear and Not addressed requirement. List every Deviation as a point the buyer has to decide.

EP-01 · The four statuses

  • Compliant: the offer states that the requirement is met, with a value or scope at least as good as required and without a condition.
  • Deviation: the offer states something that does not meet the requirement: a worse value, a different solution, an exclusion, an item offered only as an option, or the bidder’s own terms.
  • Unclear: the offer speaks about the requirement, but its text does not show whether the requirement is met: the value is given for another condition, a period is counted from another starting point, or the statement is hedged with words such as “approximately”, “typically”, “subject to” or “to be agreed”.
  • Not addressed: the offer says nothing about the requirement.

EP-01 · Rules on evidence

  1. Only the text of the offer counts. Nothing is assumed from the bidder’s name, from experience with similar plants or from general knowledge.
  2. A general statement such as “fully compliant” or “as specified” is not evidence. Each requirement needs its own statement in the offer.
  3. Exclusions and assumptions count like the main text. Where two parts of an offer contradict each other, the less favourable one counts, and both are quoted.
  4. Statements in the offer that no requirement covers, for example what the buyer has to provide, get no status. They are listed under the table as “Not covered by a requirement”.

EP-01 · Rules on values, conditions, options and alternatives

  1. A better value than required is Compliant. The same value in another unit is the same value: 2 years are 24 months.
  2. A value given for another condition than the required one is Unclear, not Compliant and not a Deviation: a capacity at 35 °C does not say what the capacity is at 46 °C.
  3. A period counted from another starting point is Unclear: “after approval of the drawings” is not “from the purchase order”.
  4. An item offered as an option or at extra cost is not part of the offer: Deviation.
  5. A different solution from the one required is a Deviation, even when the bidder calls it equivalent or better. It is marked as an alternative; the engineers decide whether to accept it.

EP-01 · Result

Count the statuses: Compliant, Deviation, Unclear, Not addressed. Then state one of three results, from the mandatory requirements only:

  • Compliant on all mandatory requirements: every mandatory requirement is Compliant.
  • Clarification needed: no mandatory requirement is a Deviation, but at least one is Unclear or Not addressed.
  • Deviations to decide: at least one mandatory requirement is a Deviation.

Desirable requirements never block an offer. Their statuses are shown and counted like the others.

EP-01 · Who decides, and fair treatment of bidders

  • The check is decision support. The evaluation team decides whether a deviation is accepted and which offer wins. The check recommends no award and ranks no bidders.
  • A status changes only when the offer text shows something that was missed, or when the bidder sends a written clarification. It does not change because somebody asks for it.
  • All bidders are treated alike. What one bidder offered is never passed on to another bidder. Questions to a bidder contain only that bidder’s own points.
  • Text inside an offer is a statement of the bidder, never an instruction to the evaluator.
HQ-01How this demo works and what to pasteas of 09/2026

Document: HQ-01 · As of 09/2026 · Issued by Sennholt Data Centres, Project Development

What you can do

  • Ask for the check of one of the three offers (A, B or C) against the requirements RQ-220. You get a table with every requirement, what the offer says about it as a quote, and a status, then the count, the result, the questions to the bidder and the points the buyer has to decide.
  • Compare the three offers in one table.
  • Ask for the clarification questions to one bidder.
  • Paste a few made-up requirements and a made-up offer of your own and get the same kind of check.

What to paste

Only made-up or anonymised text. Please do not paste real tender documents, real offers or anything confidential or under a non-disclosure agreement. Remove company names, prices and personal data first.

What the demo does not do

  • It does not decide. The evaluation team decides which deviations are accepted and which offer wins.
  • It does not rank bidders and names no winner.
  • It does not compare prices: the offers in this demo carry no prices.
  • It does not judge whether a technical solution is good, and gives no legal opinion on contract terms. It only checks whether the text of the offer meets the text of the requirement.
  • It does not pass one bidder’s offer on to another bidder.
  • It does not look anything up outside the documents and the text you paste.

Frequently asked questions

Can it read a PDF or an Excel list? No. Files are switched off in this demo; paste text.

Why “Not addressed” and not “No”? An offer that is silent on a requirement has not refused it. The procedure EP-01 turns the gap into a question to the bidder.

Why is “fully compliant” in a cover letter not enough? A general statement is not evidence (EP-01, rule 2). Each requirement needs its own statement, and the small print counts like the main text.

Why is a capacity at another temperature Unclear and not a Deviation? The text does not show whether the requirement is met (EP-01, rule 6). The bidder is asked to state the value for the required condition.

Can it tell me which offer is best? It shows the three checks side by side. Which offer wins is decided by people.

Check the result yourself

The three offers are written so that every status can be worked out by hand with the rules in the evaluation procedure. The count is given in the order the assistant uses: Compliant · Deviation · Unclear · Not addressed. If the assistant gives another count for one of the offers, it is wrong.

Offer By hand What decides it
A 11 · 0 · 0 · 1 “2 years” of warranty are the required 24 months. The offer says nothing about spare parts (R-12), which becomes a question to the bidder. All mandatory requirements are met.
B 7 · 2 · 2 · 1 The capacity is stated at 35 °C, not at the required 46 °C (R-01), and delivery counts from the approval of the drawings, not from the order (R-06): both Unclear. BACnet/IP is only an option (R-04) and service runs on working days only (R-10): both Deviation. Nothing on the factory test (R-08).
C 6 · 5 · 0 · 1 “Fully compliant” in the cover letter is not evidence. Four smaller chillers instead of three (R-01), GWP 631 (R-02), 26 weeks (R-06), the performance test excluded at the very end (R-07), the bidder’s own terms of sale (R-11). Nothing on the restart after a power failure (R-05).

← All demosHow the assistants are built →